If they start talking about Open and Closed Loop PC, tell them you want Inner/Outer Closed Loop PC. Inner loop power control is performed by the NodeB to set the transmit power of the UE and BTS to compensate for signal variations due to fading or pathloss to maintain the set SIR (occurs up to 1500 times per sec). Outer loop power control is performed by the RNC to set the target SIR based on the required BER/BLER for the requested services (occurs up to 100 times per sec).